Knowledge Center
Selection guides & process knowledge
Practical selection methods and FAQs distilled from real product process data.
Guides
22 articlesHow to Choose a Cleaner: Material → Contamination → Chemistry
Choose a cleaner by matching substrate tolerance and contaminant type — this decides neutral, alkaline, high-alkaline or solvent chemistry.
Choosing an Etchant: Metal Type & Selectivity Matter
Etchants are metal-specific — Ti, Mo, Ru and W each need their own system; mixing causes attack or loss of control.
Display Rework De-gumming: Cold-soak Essentials
ACF/OCA/lamination rework favors swelling-peel; temperature and soak time determine substrate safety.
Wafer Cleaning: RCA and the SC1/SC2 System
The RCA standard wet process uses SC1 for particles/organics and SC2 for ionic metals, aided by megasonics to lift yield.
TGV Through-Glass Via Etching: Laser Modify + Wet Etch
Glass has no natural etch direction like silicon; TGV uses femtosecond laser modification plus wet etch to achieve high aspect-ratio vias.
Stencil Cleaning: Aqueous/Semi-aqueous & Flux Residue
Match the flux type and aperture geometry: aqueous/semi-aqueous emulsify and disperse, solvents dissolve — each with trade-offs.
OCA Display Rework: Swell-peel & Substrate Protection
OCA is mostly acrylic/silicone; rework uses swelling to weaken adhesion, and temperature/soak time are the key to substrate safety.
Optical Glass Cleaning: Grinding, Coating & De-ink/Strip
Optical glass runs cutting, edging, grinding and polishing; cleaning must match each step, and coatings are highly sensitive to strong alkali.
Display ITO Etching & Patterning
ITO is the key transparent conductor in touch/display; etching must balance undercut control with selectivity to the substrate and other films.
Metal & Plastic Finishing: Dewax, Strip & Deplate
Finish treatment on metal and plastic first identifies the soil (wax/oil/paint/plating), then chooses alkaline, acidic or solvent routes — substrate tolerance is the floor.
What replaces graphite molds for glass hot bending when mold life is too short?
Graphite molds degrade by oxidation/carbonisation at high temperature. The alternative is carbon-based composite molds such as CC-3D: 750 °C+ service temperature and 50×+ the service life of graphite.
Which mold for 750 °C microcrystalline glass bending, and why does graphite carbonise?
Microcrystalline glass bending needs 750 °C+. Graphite oxidises and carbonises badly there; CC-3D carbon-based composite molds do not, and last 50×+ longer.
CC-3D carbon-based composite mold: specifications and service-life advantage
CC-3D key figures: carbon-based composite (carbonfibre-reinforced ceramic matrix); 750 °C+ service temperature; 3D hyperboloid/large-curvature forming; ~680–700 °C for normal cover glass; 50×+ graphite mold life.
How to select cleaning chemistry for FOUP / FOSB carriers
Select by carrier material (PC ESD / CBM ESD / PEI ESD differ in temperature and alkali tolerance), then by contaminant (particles / organics / ions / resist residue). SP-Clear covers this with 5 grades.
How to clean post-CMP wafers without attacking Cu/W interconnect?
The key is a mild-alkaline window plus metal-ion capture — overly strong alkali or overly strong complexing attacks copper. PCMP-100 runs at pH 9.0–9.8 with acceptance targets of <0.1 particles/cm² (≥0.16 μm) and Na/Cu/Fe < 10 ppb.
Domestic alternative for post-thinning wafer cleaning
TW-100, an SC1-improved system, suits post-thinning cleaning: two-component 5X concentrate at A:B:DI = 1:1:5 mixed fresh, 40–60 °C for 5–10 min, with targets of <100 particles/wafer (≥0.3 μm) and Fe/Cu/Zn < 10 ppb.
Which chemistry for TGV via etching — fluorine or hot-alkali route?
For the femtosecond-laser-modification + hot-alkali selective etch route, GE-K1 runs at 110±5 °C: the modified zone is selectively removed into a via while bulk glass is barely etched, and it avoids highly toxic hydrofluoric acid.
Cleaning coated optical glass without damaging the coating or overflowing the tank
Two hard constraints: chemistry mild on the deposited film (neutral system) and no foaming in spray operation. ZL-001 uses a neutral system (3–10% working solution) with a low-foam design, cleaning in 1–3 min at 45–50 °C without tank overflow or spray-pressure loss.
Can a vacuum-deposited chrome coating (mirror-silver finish) be stripped off glass without strong acid or hydrofluoric acid?
Yes. For vacuum-deposited chrome coatings (mirror-silver finish) on glass, J360 uses an ambient-temperature eco-friendly acidic route free of hydrofluoric acid and potassium ferricyanide, stripping in 2–5 min by ambient immersion or spray, replacing traditional strong-acid systems that usually need heating.
How to remove stubborn screen-print ink from phone glass?
Aqueous alkaline boil-off often fails on stubborn screen-print ink. Match the ink system: L506 for TOYO inks (alkali + penetrant dual channel); BL-7M056-V2 for high-volume back-cover/frame stripping (80 °C, ~7 min, 1581 parts validated); L515 high-solvent custom grades for unusual inks.
How to de-bond OCA/laminating adhesive without damaging the AF coating?
The key is the solvent route plus wetting design: an aromatic-alcohol penetrant system with non-ionic wetting components speeds interfacial spreading and penetration while protecting the AF coating throughout (L715 / L716).
How to clean oil and coolant residue before curved-glass hot bending?
Pre-bending cleaning must remove machining oils and coolant residue; otherwise they convert into pits, haze and mold contamination in the hot zone. L18S is a medium-strong alkaline aqueous system that handles both in one step.
FAQ
25 questionsQWhy must aqueous/semi-aqueous cleaners be rinsed thoroughly?+
QWhy can PFA carriers take strong alkali but PC cannot?+
QHow do I detect etch endpoint?+
QCan one bath do both ink stripping and coating stripping?+
QWhy mix post-thinning cleaner fresh?+
QWhy control developer temperature strictly?+
QWhy is ITO typically etched with acid rather than alkali?+
QHow small can a TGV via be made?+
QAre dewaxing and degreasing the same?+
QWhy does a graphite mold carbonise?+
QHow much longer does a carbon-based composite mold last?+
QWhy must FOUP cleaning be low-foam?+
QWhat causes reticle-box haze?+
QCan a vacuum-deposited chrome coating be stripped off glass without hydrofluoric acid?+
QWhy can't post-coating cleaning use strong alkali or high temperature?+
QAlkali or solvent for stubborn screen-print ink?+
QWill de-bonding agents damage the screen's AF coating?+
QWhich chemistry cleans wafers after backside thinning?+
QWhat matters when selecting an ITO etchant?+
QHow to choose degreasing chemistry for aluminium and stainless CNC parts?+
QWhat cleans wafers after CMP?+
QHow are post-dry-etch residues removed from wafers?+
QWhich grinding fluid is used for glass CNC machining?+
QWhat replaces graphite trays for high-temperature sintering and heat treatment?+
QHow is blue-tape residue removed from wafers?+
Need technical support or a sample?
Tell us your substrate, contamination and process conditions — our process engineers will recommend a grade and arrange sample validation.
- Phone
- +86 769-82786068
- sales@sempurion.com
- Website
- www.sempurion.com
- Address